Pressure setting range
0…60 bar
Maximum permissible accidental pressure
150 bar
Destruction pressure
300 bar
Materials in contact with fluid
Fluorocarbon FPM
Stainless steel AISI 316L
Operating position
Any position
Protection type
Load short-circuit
Reverse polarity
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to ISO 10605 criteria A 15 kV air, 15 kV contact
Susceptibility to electromagnetic fields conforming to ISO 11452-2 criteria A 100 V/m 200…2000 MHz
Susceptibility to electromagnetic fields conforming to ISO 11452-4 criteria A 100 mA 20…400 MHz
Susceptibility to conducted disturbances conforming to EN/IEC 61000-4-6 criteria A 30 V 0.15...80 MHz
Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 criteria A 4 kV
Susceptibility to conducted transient disturbances conforming to ISO 7637-2 criteria B level 3
[Uimp] rated impulse withstand voltage
0.5 kV
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
+/- 0.5 % of the measuring range
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0.02 % of measuring range/°K
Drift of the zero point
+/- 0.02 % of measuring range/°K
Repeat accuracy
+/- 0.5 % of the measuring range
Mechanical durability
10000000 cycles