XCKM106H7

Limit switch, Limit switches XC Standard, XCKM, cats whisker, 1NC+1 NO, snap action, 1/2NPT

arrow

Commercialized

green premium

Expand all

Datasheet

Range of Product
Telemecanique Limit switches XC Standard
Series name
Standard format
Product or Component Type
Limit switch
Device short name
XCKM
Body type
Fixed
Head type
Multi-directional head
Material
Metal
Body material
Zamak
Fixing Mode
By the body
Movement of operating head
Multi-directional
Type of operator
Spring return cat''s whisker
Type of approach
Multi-directional approach
Cable entry
3 entries tapped for 1/2" NPT cable gland
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Snap action
Switch actuation
By any moving part
Electrical connection
Screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Contacts insulation form
Zb
Number of steps
1
Positive opening
Without
Minimum torque for tripping
1.15 lbf.in (0.13 N.m)
Minimum actuation speed
0.01 m/min
Maximum actuation speed
3.28 ft/s (1 m/s)
Contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A AC
[Ui] rated insulation voltage
300 VUL 508
500 V 3)IEC 60947-1
300 VCSA C22.2 No 14
Maximum resistance across terminals
25 MOhm IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV IEC 60664
6 kV IEC 60947-1
Short-circuit protection
10 A cartridge fuse gG
Electrical durability
5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical durability
10000000 cycles
Width
2.52 in (64 mm)
Height
2.52 in (64 mm)
Depth
1.18 in (30 mm)
Terminals description ISO n°1
(21-22)NC
(13-14)NO
Shock resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration resistance
25 gn 10…500 Hz)EN/IEC 60068-2-6
IP degree of protection
IP66 conforming to EN/IEC 60529
IK degree of protection
IK05 conforming to EN 50102
Electrical shock protection class
Class I IEC 61140
Class I NF C 20-030
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Protective treatment
TC
Product Certifications
CSA
UL
CCC
Standards
EN 60947-5-1
EN 60204-1
IEC 60204-1
IEC 60947-5-1
UL 508
CSA C22.2 No 14
Category
US1000T22416
Discount Schedule
000T
GTIN
3389118120457
Returnability
No
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Sustainable offer status
Green Premium product
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
RoHS exemption information
Yes
Circularity Profile
No need of specific recycling operations
Warranty
18 months

Expand all

Technical Drawings

Dimensions

epds
epds

(1) Tapped entry for ½ “NPT

Ø : 2 elongated holes Ø 5.2 x 6.2

(1) Tapped entry for 1/2" NPT conduit

(2) Pg 11 threaded sleeve

Mounting with Cable Entry

Position of Cable Gland

epds

(1) Recommended

(2) To be avoided

Wiring Diagram

2-pole NC + NO Snap Action

epds

Characteristics of Actuation

Switch Actuation by Any Moving Part

epds

Functionnal Diagram

epds

(1) Closed

(2) Open

(3) Tripping

(4) Resetting

Back to top

arrow