Electrical connection
Screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Contacts insulation form
Zb
Positive opening minimum force
30 N
Minimum force for tripping
15 N
Minimum actuation speed
0.01 m/min
Maximum actuation speed
1.64 ft/s (0.5 m/s)
Repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 VUL 508
500 V 3)IEC 60947-1
300 VCSA C22.2 No 14
[Uimp] rated impulse withstand voltage
6 kV IEC 60664
6 kV IEC 60947-1
Short-circuit protection
10 A cartridge fuse gG
Electrical durability
5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical durability
10000000 cycles
Net Weight
0.30 lb(US) (0.135 kg)
Terminals description ISO n°1
(13-14)NO
(21-22)NC