XZBWR2STT24

Programmable receiver, 4 PNP, 200 mA, 24 V DC, 2 pusbuttons, 6 LEDs

arrow

Comercializado

Expandir todo

Ficha de datos

Product or component type
Programmable receiver
Device application
Interface to PLC
Product compatibility
Radio transmitter XZBWE
Function of module
Receiver unit for remote sensor
Maximum number of transceivers
ZigBee: <2
Nominal output current
0.8 A at 24 V DC
Output type
Transistor PNP
Output contacts
4 PNP
Time delay range
0.5 s (tolerance: - 15...15 %)
Starting time
<= 400 ms
Maximum switching current
200 mA DC
Minimum switching current
10 mA
[Us] rated supply voltage
24 V DC - 15...20 %
Maximum voltage drop
<2 V (nominal output current: 200 mA)
Communication port protocol
Zigbee green power at 2.4 GHz
Maximum sensing distance
100 m in free field
25 m in a metal enclosure
Response time
< 30 ms after sensor change
Number of channels
2 per receiver
Utilisation category
DC-13 conforming to EN/IEC 60947-5-1
Maximum power consumption in W
26 W DC
Breaking capacity
4.8 W (per output)
Short-circuit protection
1 A fuse type fast blow
Operating position
Any position without derating
Electrical connection
1 conductor cable 0.14…2.5 mm² AWG 26...AWG 14 solid without cable end conforming to IEC 60947-1
2 conductors cable 0.14…1.5 mm² AWG 26...AWG 16 solid without cable end conforming to IEC 60947-1
1 conductor cable 0.14…4 mm² AWG 26...AWG 12 flexible with cable end conforming to IEC 60947-1
2 conductors cable 0.14…1.5 mm² AWG 26...AWG 16 flexible with cable end conforming to IEC 60947-1
Tightening torque
0.5…1 N.m conforming to EN/IEC 60947-1
Housing material
Self-extinguishing plastic
Status LED
1 LED green for power ON
1 LED green and yellow for reception signal
4 LEDs green for output active
Mounting support
35 mm symmetrical DIN rail conforming to EN/IEC 60715
Mounting plate
Rated short-duration power frequency withstand voltage
1 kV 50 Hz conforming to EN/IEC 60947-5-1
[Uimp] rated impulse withstand voltage
0.8 kV
Width
36 mm
Height
108 mm
Depth
75 mm
Net weight
0.13 kg
Marking
CE
Surge withstand
0.5 kV differential mode conforming to IEC 61000-4-5
1 kV common mode conforming to IEC 61000-4-5
Standards
EN/IEC 60947-5-1
EN/IEC 60947-1
Ambient air temperature for storage
-40…70 °C
Relative humidity
90 % at -20…55 °C, without condensation conforming to ETSI EN 300 328
Vibration resistance
+/- 7.5 mm (f= 5…14 Hz) conforming to IEC 60068-2-6
2 gn (f= 8…150 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn (duration = 16 ms) for 6000 shocks conforming to IEC 60068-2-27
IP degree of protection
IP20 (casing) conforming to IEC 60529
IP20 (terminals) conforming to IEC 60529
Pollution degree
2 conforming to IEC 60664-1
Overvoltage category
III conforming to IEC 60664-1
Insulation resistance
> 500 MOhm at 500 V DC conforming to NF C 20-030
[Ui] rated insulation voltage
60 V conforming to IEC 60664-1
Electromagnetic compatibility
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Conducted and radiated emissions class B conforming to CISPR 22
Electrostatic discharge immunity test 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electrostatic discharge immunity test 6 kV on contact (on metal parts) conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields 10 V/m, 80 MHz...1 GHz at 3 m conforming to IEC 61000-4-3
Susceptibility to electromagnetic fields 3 V/m, 1.4 MHz…2 GHz at 3 m conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test 2 kV power supply wires conforming to IEC 61000-4-4
Conducted RF disturbances 10 V conforming to IEC 61000-4-6
Radiated emission conforming to ETSI EN 301 489-17
Conducted emission conforming to ETSI EN 301 489-17
Radiated emission conforming to ETSI EN 300 328
Electrical fast transient/burst immunity test 1 kV PNP output wires conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test 0.5 kV differential mode conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test 1 kV common mode conforming to IEC 61000-4-5
Immunity to microbreaks and voltage drops 7 ms conforming to IEC 61000-4-11
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.400 cm
Package 1 Width
9.800 cm
Package 1 Length
13.000 cm
Package 1 Weight
128.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
22
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
3.137 kg
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expandir todo

Dibujos tecnicos

Receiver Dimensions

epds

Receiver Wiring Diagram

epds

(1) 400 mA fast-blow fuse

(2) Imax = 200 mA

Receiver Mounting

epds

Receiver Mounting

epds

Receiver Mounting

epds

(1) Drive

(2) Power Supply or PLC

Unobstructed Mounting

epds

(1) Typical values that may be modified by the application environment.

Mounting in a Metal Cabinet

epds

(1) Typical values that may be modified by the application environment.

Expandir todo

Documentos y Descargas

Nombre del documento
Fecha
Tamaño

Back to top

arrow