XMLA001S2S13

Pressure sensor XMLA 1 bar - fixed scale 1 threshold - 1 C/O - with display

Discontinued End of commercialization date : 30 December 2017 End of service date : 30 December 2017

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electromechanical pressure sensor
Pressure sensor type
Electromechanical pressure sensor
Device short name
XMLA
Pressure rating
1 bar
Controlled fluid
Corrosive fluid (0…160 °C)
Fresh water (0…160 °C)
Fluid connection type
1/4" - 18 NPTF (female)
Electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
AWG gauge
AWG 20...AWG 14
Cable entry
Cable gland 7…13 mm
Contacts type and composition
1 C/O
Product specific application
-
Pressure switch type of operation
Detection of 1 single threshold
Electrical circuit type
Control circuit
Scale type
Fixed differential
Local display
With
Adjustable range of switching point on rising pressure
0.03…1 bar
Adjustable range of switching point on falling pressure
0.01…0.96 bar
Maximum permissible accidental pressure
2.25 bar
Destruction pressure
4.5 bar
Pressure actuator
Diaphragm
Materials in contact with fluid
PTFE
316L stainless steel
Enclosure material
Zinc alloy
[In] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to IEC 60947-5-1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to IEC 60947-5-1
Natural differential at low setting
0.02 bar (+/- 0.01 bar)
Natural differential at high setting
0.04 bar (+/- 0.01 bar)
Maximum permissible pressure - per cycle
1.25 bar
Terminal block type
4 terminals
Maximum operating rate
120 cyc/mn
Repeat accuracy
2 %
[Ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Auxiliary contacts operation
Snap action
Contacts material
Silver contacts
Maximum resistance across terminals
25 mOhm conforming to IEC 255-7 category 3
25 mOhm conforming to NF C 93-050 method A
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Mechanical durability
4000000 cycles
Setting
External
Height
162 mm
Depth
110 mm
Width
110 mm
Net weight
2.555 kg
Standards
IEC 60947-5-1
CE
CSA C22.2 No 14
UL 508
Product certifications
CSA
LROS (Lloyds register of shipping)
UL
CCC
BV
Protective treatment
TC standard version
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Operating position
Any position
Vibration resistance
2 gn conforming to IEC 60068-2-6 (f = 30…500 Hz)
Shock resistance
30 gn conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
IP degree of protection
IP66 conforming to IEC 60529
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Warranty
18 months

Expand all

Technical Drawings

Dimensions

epds
  • Ø a = 110 mm / 4.33 in.
  • (1) 1 fluid entry, tapped 1/4" NPTF
  • (2) 1 electrical connections entry, tapped 1/2" NPT

Wiring Diagram

Terminal Model

epds

Operating Curves

epds
  • (y) Rising pressure
  • (x) Falling pressure
epds
  • (y) Rising pressure
  • (x) Falling pressure
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • (2) Non adjustable value
  • PH : High point
  • PB : Below point

Back to top

arrow