XMLP004GC21FQ

Pressure transmitter 4bar - 4..20mA - G1/4A male - FPM - DIN - bulk pack 25

Discontinued End of commercialization date : 08 December 2020 End of service date : 08 December 2020

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electronic pressure sensors
Pressure sensor type
Pressure transmitter
Pressure sensor name
XMLP
Electrical circuit type
Control circuit
Pressure rating
4 bar
Local display
Without
Controlled fluid
Fresh water (0…125 °C)
Air (-15…125 °C)
Gas (-15…125 °C)
Hydraulic oil (-15…125 °C)
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
Electrical connection
1 male connector EN 175301-803-A (ex DIN43650) 3 pins
[Us] rated supply voltage
12...24 V DC SELV (voltage limits: 7…33 V)
Current consumption
< 23 mA
Type of output signal
Analogue
Analogue output function
4...20 mA, 2-wire
Quantity per set
Set of 25
Type of packing
Group
Pressure setting range
0…4 bar
Maximum permissible accidental pressure
12 bar
Destruction pressure
16 bar
Materials in contact with fluid
Stainless steel AISI 316L
Ceramic
Fluorocarbon FPM
Operating position
Any position
Protection type
Load short-circuit
Reverse polarity
Electromagnetic compatibility
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz
Radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm
Immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 4 kV
[Uimp] rated impulse withstand voltage
0.5 kV
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
+/- 0.5 % of the measuring range
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0.02 % of measuring range/°K
Drift of the zero point
+/- 0.02 % of measuring range/°K
Repeat accuracy
+/- 0.25 % of the measuring range
Mechanical durability
10000000 cycles
Net weight
0.095 kg
Diameter
26 mm
Length
55 mm
Standards
NSF ANSI 61
IEC 61326-2-3
Product certifications
RCM
CE
cULus
Ambient air temperature for operation
-30…85 °C
Ambient air temperature for storage
-50…100 °C
Vibration resistance
20 gn (f = 10…2000 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
Unit Type of Package 1
PCE
Number of Units in Package 1
1
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expand all

Technical Drawings

Dimensions

epds
  • (1) SW24 tightening torque ≤ 25 N.m / 221 lb-in

Connection and Schema

Wiring Diagram

epds
  • (a) I out

2-Wire Technique (4-20 mA)

Performance Curves

Curves

epds

Expand all

Documents & Downloads

Document name
Date
Size

Back to top

arrow