XC1AC121

Limit switch, Limit switches XC Standard, XC1AC, end plunger, 1NC+1 NO, break before make

Fuori commercializzazione Data di fine commercializzazione : 30 June 2022 Data di fine service : 30 June 2022

XC1AC121 is replaced by the following product:

img
XCKJ161

Limit switch, XC Standard, XCKJ, metal end plunger, 1NC+1 NO, snap action, Pg13

Commercialised

Commercialised

Quantity :  1

Espandi selezione

Datasheet

Range of product
OsiSense XC
Series name
Special format
Product or component type
Limit switch
Product specific application
Materials handling
Device short name
XC1AC
Sensor design
-
Body type
Fixed
Head type
Plunger head
Material
Metal
Fixing mode
By the body
Movement of operating head
Linear
Type of operator
Spring return plunger metal
Switch actuation
On end
Type of approach
Vertical approach, 1 direction
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...1 x 2.5 mm²
Cable entry
3 entries tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, break before make
Number of steps
1
Positive opening
Without
Minimum force for tripping
33 N
Contacts insulation form
Zb
Maximum actuation speed
0.5 m/s
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
500 V AC conforming to IEC 60947-5-1
500 V AC conforming to NF C 20-040
600 V DC conforming to IEC 60947-5-1
600 V DC conforming to NF C 20-040
600 V AC conforming to CSA C22.2 No 14
600 V DC conforming to CSA C22.2 No 14
Maximum resistance across terminals
8 mOhm
Short-circuit protection
10 A cartridge fuse, type gG
Electrical durability
1000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 110 V, 900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 230 V, 1900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 48 V, 450 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, inductive load type, 110 V, 100 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, inductive load type, 230 V, 95 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, inductive load type, 48 V, 100 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 110 V, 350 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 230 V, 430 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 48 V, 170 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13, inductive load type, 110 V, 40 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13, inductive load type, 230 V, 33 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13, inductive load type, 48 V, 35 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
10000000 cycles
Width
77 mm
Height
130 mm
Depth
44 mm
Net weight
0.53 kg
Terminals description ISO n°1
(11-12)NC
(13-14)NO
Shock resistance
95 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
9 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection
IP65 conforming to IEC 60529
IP65 conforming to NF C 20-010
Electrical shock protection class
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Protective treatment
TC
Operating position
Any position
Product certifications
CSA
Standards
IEC 60337-1
IEC 60947-5-1
VDE 0660-200
EN 60947-5-1
CSA C22.2 No 14
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.5 cm
Package 1 Width
9 cm
Package 1 Length
15 cm
Package 1 Weight
560 g
REACh Regulation
EU RoHS Directive
Not applicable, out of EU RoHS legal scope
Circularity Profile
No need of specific recycling operations
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Espandi selezione

Disegni tecnici

Dimensions

epds
  • (1) 3 tapped entries for Pg 13.5 cable gland

Adaptator Dimensions for IS0 M20 x 1.5

epds

Wiring Diagram

2-pole NC + NO Break Before Make, Slow Break

epds

Characteristics of Actuation

Switch Actuation on End

epds

Functionnal Diagram

epds
  • (1) Closed
  • (2) Open

Espandi selezione

Documenti & Downloads

Nome del documento
Data
Taglia

Back to top

arrow