Pressure setting range
-99.97…0.00 kPa
Maximum permissible accidental pressure
303.37 kPa
Destruction pressure
503.32 kPa
Materials in contact with fluid
Ceramic
Stainless steel AISI 316L
Fluorocarbon FPM
Operating position
Any position
Protection type
Reverse polarity
Load short-circuit
Electromagnetic compatibility
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV
Radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm
Immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz
[Uimp] rated impulse withstand voltage
0.5 kV
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
+/- 0.5 % of the measuring range
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0.02 % of measuring range/°K
Drift of the zero point
+/- 0.02 % of measuring range/°K
Repeat accuracy
+/- 0.25 % of the measuring range
Mechanical durability
10000000 cycles