HL100WDL2M8

Limit switch, L100/300, L100 mill 2 contacts, spring return, CW, 1/2" NPT

Descontinuado Fecha de fin de comercialización : 20 April 2022 Fecha de fin del servicio : 20 April 2022

Expandir todo

Ficha de datos

Range of product
L100/300
Series name
Severe duty mill
Product or component type
Limit switch
Product specific application
Mill switch
Device short name
L100
L300
Body type
Fixed
Head type
Rotary head
Sale per indivisible quantity
1
Base plate style
Style 2
Body material
Cast aluminium
Fixing mode
By the body
Type of operator
spring return without operating lever
Contact sequence number
8
Function available
-
Switch actuation
From left
CW
Type of approach
Lateral approach
Electrical connection
Screw-clamp terminals AWG 22...AWG 12
Cable entry
1 entry for 1/2" - 14 NPT conforming to ANSI B1.20.1
Number of poles
2
CW operation contacts
2 NO
CCW operation contacts
2 NC
Contacts style
A
Switch function
DPST-NC-DB
Contact form
Form YY
Contacts material
90/10 AgCdO on copper backing stationary contact
Silver on steel backing moveable contact
Contacts usage
-
Contact operation
Snap action
Positive opening
Without
Minimum torque for tripping
190 ozf.in
Maximum actuation speed
90 ft/min with 45° cam angle, levers only
130 ft/min with 30° cam angle, levers only
Tripping angle
17 °
Maximum displacement angle
80 °
Repeat accuracy
+/- 0.03 %
Contact code designation
A600, AC (Ue = 600 V) Ie = 5 A conforming to NEMA rating designation
A600, AC (Ue = 480 V) Ie = 6.25 A conforming to NEMA rating designation
A600, AC (Ue = 240 V) Ie = 12.5 A conforming to NEMA rating designation
A600, AC (Ue = 120 V) Ie = 20 A conforming to NEMA rating designation
P600, DC (Ue = 600 V) Ie = 0.2 A conforming to NEMA rating designation
P600, DC (Ue = 250 V) Ie = 1 A conforming to NEMA rating designation
P600, DC (Ue = 120 V) Ie = 5 A conforming to NEMA rating designation
[Ithe] conventional enclosed thermal current
20 A
[Ui] rated insulation voltage
600 V (pollution degree 3) conforming to IEC 60947-1
600 V (pollution degree 3) conforming to UL 508
600 V (pollution degree 3) conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
2.5 kV AC for 1 minute conforming to CE
2.2 kV AC for 1 minute conforming to UL
2.64 kV AC for 1 minute conforming to CSA
Short-circuit protection
20 A Bussmann class CC KTK-R-20 non-time delay
Width
57.15 mm
Height
125.73 mm
Depth
86.61 mm
Net weight
0.68 kg
Terminals description ISO n°1
(1-2) left side contact
(5-6) right side contact
Shock resistance
30 gn for 9 ms conforming to IEC 60068-2-27
Vibration resistance
10 gn (f= 10…55 Hz) conforming to IEC 60068-2-6
NEMA degree of protection
NEMA 1 conforming to Nema type 250
NEMA 2 conforming to Nema type 250
NEMA 4 conforming to Nema type 250
NEMA 12 conforming to Nema type 250
NEMA 13 conforming to Nema type 250
IP degree of protection
IP67 conforming to IEC 60529
Electrical shock protection class
Class 0 conforming to IEC 61140
Ambient air temperature for operation
-18…177 °C
Ambient air temperature for storage
-18…177 °C
Protective treatment
Corrosion resistant gray paint
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.842 cm
Package 1 Width
7.112 cm
Package 1 Length
12.954 cm
Package 1 Weight
680.389 g
EU RoHS Directive
Not applicable, out of EU RoHS legal scope
Environmental Disclosure
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Back to top

arrow