Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to EN/IEC 60536
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Marking
II2 D-Ex tb IIIC T85°C Db IP67
Product certifications
IEC-Ex INE 17.0020X
INERIS 04ATEX0014X
Standards
EN/IEC 60079-31
EN/IEC 60079-0
Directives
2014/34/EU - ATEX directive