XCKJ10513H29

Limit switch, XC Standard, XCKJ, steel roller lever, 1NC+1 NO, snap action, M20

arrow

Commercialized

green premium

Expand all

Datasheet

Range of product
Telemecanique Limit switches XC Standard
Series name
Standard format
Product or component type
Limit switch
Device short name
XCKJ
Sensor design
Form A conforming to CENELEC EN 50041
Body type
Fixed
Head type
Rotary head
Material
Metal
Body material
Zamak
Head material
Zamak
Fixing mode
By the body
Movement of operating head
Rotary
Type of operator
Spring return roller lever metal
Type of approach
Lateral approach, 1 or 2 programmable direction
Cable entry
1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Snap action
Switch actuation
By 30° cam
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Contacts insulation form
Zb
Number of steps
1
Positive opening
With
Positive opening minimum torque
0.5 N.m
Minimum torque for tripping
0.25 N.m
Maximum actuation speed
1.5 m/s
[Ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection
10 A cartridge fuse, type gG
Electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
30000000 cycles
Width
40 mm
Height
77 mm
Depth
44 mm
Net weight
0.49 kg
Terminals description ISO n°1
(21-22)NC
(13-14)NO
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection
IP66 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
Overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Protective treatment
TH
Product certifications
UL
CCC
CSA
Standards
UL 508
IEC 60947-5-1
IEC 60204-1
IEC 60204-1
CENELEC EN 50041
CSA C22.2 No 14
IEC 60947-5-1
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.300 cm
Package 1 Width
7.000 cm
Package 1 Length
13.000 cm
Package 1 Weight
482.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
18
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
9.130 kg
Unit Type of Package 3
P06
Number of Units in Package 3
288
Package 3 Height
75.000 cm
Package 3 Width
60.000 cm
Package 3 Length
80.000 cm
Package 3 Weight
154.596 kg
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
Circularity Profile
No need of specific recycling operations
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Expand all

Technical Drawings

Dimensions

epds

(1) 1 tapped entry M20 x 1.5

Mounting with Cable Entry

Position of Cable Gland

epds

(1) Recommended

(2) To be avoided

Mounting with Rotary Heads and Levers

Type of Cam

epds

(1) Recommended

(2) To be avoided

Setting-up with Lever Head

epds

(1) 5° steps throughout 360° / Tightening torque (Min : 1) (Max : 1.5)

(2) 45° steps throughout 360° / Tightening torque (Min : 1) (Max : 1.5)

(a) Tightening torque (Min : 1) (Max : 1.5)

Setting-up with Head ZCKE05

Direction of Actuation Programming

epds

Wiring Diagram

2-pole NC + NO Snap Action

epds

Characteristics of Actuation

Switch Actuation on End

epds

Functionnal Diagram

epds

(P) Positive opening point

(1) NC contact with positive opening operation

(2) Closed

(3) Open

(4) Tripping

(5) Resetting

Expand all

Related products & accessoires

img
XCMZ07

Spacer for angular positioning of head with adjustable lever, for limit switch

img
ZCE05

Limit switch head, Limit switches XC Standard, ZCE, without lever spring return left or right actuation

img
DE9RA1012

Telemecanique Safety switches XCS -1/2' NPT conduit adaptor, for plastic switch XCSPA

img
ZCKZ020

Indicator module 1 LED with cover, 24 VDC, for fixed XCKJ

img
ZCKZ021

Indicator module 2 LEDs with cover, 24 VDC, for fixed XCKJ

img
ZCKZ034

Indicator module 2 neons with cover, 220/240 VAC, for fixed XCKJ

Back to top

arrow