XU2S18KP340L5T

Light curtain transmitter XU2-S - detection of body - 750..1200 mm - 12..24 V

Discontinued End of commercialization date : 12 January 2022 End of service date : 12 January 2022

green premium

Expand all

Datasheet

Range of product
Telemecanique Safety light curtains XUSL
Product or component type
Safety thru-beam transmitter photo-electric sensors
Device short name
XU2S
Product compatibility
XPSCM1144P
XPSCM1144
[Sn] nominal sensing distance
8 m
Detection system
Transmitter-receiver system
[Us] rated supply voltage
12...24 V DC (10...30 V)against reverse polarity
Current consumption
<= 35 mA no-load
Line of sight type
Along case axis
Electrical connection
Pre-cabled
Cable outer diameter
5 mm
Cable length
5 m
Cable composition
3 x 0.34 mm²
Tightening torque
24 N.m fixing nut
Marking
CE
Material
Nickel plated brass: case
PMMA (polymethyl methacrylate): lenses
Net weight
0.235 kg
Ambient air temperature for operation
-25…55 °C
Ambient air temperature for storage
-40…70 °C
IP degree of protection
IP67 conforming to EN/IEC 60529
Shock resistance
30 gn 3 axes : 3 times conforming to EN/IEC 60068-2-27
Vibration resistance
7 gn (f= 10…55 Hz) conforming to EN/IEC 60068-2-6
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.7 cm
Package 1 Width
9.6 cm
Package 1 Length
13 cm
Package 1 Weight
229 g
Sustainable offer status
Green Premium product
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Expand all

Technical Drawings

Dimensions

epds
  • (1) LED
  • (2) Potentiometer

Wiring Schemes (3-wire DC)

Transmitter

epds
  • BU : Blue
  • BN : Brown
  • VI : Violet
  • (1) Test

Wiring Schemes (3-wire DC)

Beam Break Test

epds
  • BU : Blue
  • BN : Brown
  • VI : Violet
  • (1) Test
  • BU : Blue
  • BN : Brown
  • VI : Violet

Beam Break Test

epds
  • BU : Blue
  • BN : Brown
  • VI : Violet
  • (1) Test
  • BU : Blue
  • BN : Brown
  • VI : Violet
  • BU : Blue
  • BN : Brown
  • VI : Violet

Connecting to a Safety Module

epds
  • 1 : Click on Download & Documents
  • 2 : Click on System user guide

To have all connection schematics concerning our safety module, select "download and document" and download the file "Connecting to a monitoring device XU2S"

Curves

Infrared Detection Curve

epds
  • (1) Ø of beam

Curves

Verification of Correct Operation

epds
  • (1) Ø of beam
  • (1) LED off
  • (2) LED on
  • (3) Red LED
  • (4) Signal level
  • (5) Optimum alignment

Expand all