XCKJ110511

Limit switch, XC Standard, XCKJ, thermoplastic roller lever, 1C/O, snap action, Pg13

arrow

Ticarileştirildi

green premium

Tümünü genişlet

Veri sayfası

Range of product
Telemecanique Limit switches XC Standard
Series name
Standard format
Product or component type
Limit switch
Device short name
XCKJ
Sensor design
Form A conforming to CENELEC EN 50041
Body type
Plug-in body
Head type
Rotary head
Material
Metal
Body material
Zamak
Head material
Zamak
Fixing mode
By the body
Movement of operating head
Rotary
Type of operator
Spring return roller lever thermoplastic
Type of approach
Lateral approach, 1 or 2 programmable direction
Cable entry
1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm
Number of poles
1
Contacts type and composition
1 C/O
Contact operation
Snap action
Switch actuation
By 30° cam
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.75...2 x 1.5 mm²
Contacts insulation form
Zb
Number of steps
1
Positive opening
Without
Minimum torque for tripping
0.25 N.m
Maximum actuation speed
1.5 m/s
[Ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short-circuit protection
10 A cartridge fuse, type gG
Electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
30000000 cycles
Width
43 mm
Height
84 mm
Depth
36 mm
Net weight
0.48 kg
Terminals description ISO n°1
(13-14)NO
(11-12)NC
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection
IP66 conforming to IEC 60529
IK degree of protection
IK07 conforming to EN 50102
Overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Protective treatment
TH
Product certifications
CSA
UL
CCC
Standards
CSA C22.2 No 14
IEC 60947-5-1
IEC 60204-1
UL 508
CENELEC EN 50041
EN 60204-1
EN 60947-5-1
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.200 cm
Package 1 Width
7.000 cm
Package 1 Length
12.800 cm
Package 1 Weight
512.000 g
Unit Type of Package 2
S01
Number of Units in Package 2
9
Package 2 Height
15.000 cm
Package 2 Width
15.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
4.797 kg
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
Circularity Profile
No need of specific recycling operations
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Tümünü genişlet

Teknik çizimler

Dimensions

epds

(1) 1 tapped entry Pg 13.5

Mounting with Cable Entry

Position of Cable Gland

epds

(1) Recommended

(2) To be avoided

Mounting with Rotary Heads and Levers

Type of Cam

epds

(1) Recommended

(2) To be avoided

Setting-up with Lever Head

epds

(1) 5° steps throughout 360° / Tightening torque (Min : 1) (Max : 1.5)

(2) 45° steps throughout 360° / Tightening torque (Min : 1) (Max : 1.5)

(a) Tightening torque (Min : 1) (Max : 1.5)

Setting-up with Head ZCKE05

Direction of Actuation Programming

epds

Wiring Diagram

Single-pole CO Snap Action

epds

Characteristics of Actuation

Switch Actuation on End

epds

Functionnal Diagram

epds

(1) Closed

(2) Open

(3) Tripping

(4) Resetting

Tümünü genişlet

Dökümanlar & İndirmeler

Back to top

arrow