Movement of operating head
Rotary
Type of operator
Spring return without operating lever
Contact sequence number
3
Switch actuation
CW and CCW
From left or right
Type of approach
Lateral approach
Electrical connection
Screw-clamp terminals AWG 22...AWG 12
Cable entry
1 entry for Pg 13.5 DIN 40430
Contact operation
Snap action
Contacts usage
Maintained
Contacts material
Silver flashed copper
Minimum torque for tripping
12 lbf.in (1.36 N.m)
Maximum actuation speed
130 ft/min with 30° cam angle, levers only
90 ft/min with 45° cam angle, levers only
Maximum displacement angle
81 °
Repeat accuracy
+/- 0.004 in linear travel of cam on 1.5 in lever arm
Contact code designation
A600, AC (Ue = 600 V) Ie = 5 A NEMA rating designation
A600, AC (Ue = 480 V) Ie = 6.25 A NEMA rating designation
A600, AC (Ue = 240 V) Ie = 12.5 A NEMA rating designation
A600, AC (Ue = 120 V) Ie = 20 A NEMA rating designation
P600, DC (Ue = 600 V) Ie = 0.2 A NEMA rating designation
P600, DC (Ue = 250 V) Ie = 1 A NEMA rating designation
P600, DC (Ue = 120 V) Ie = 5 A NEMA rating designation
[Ithe] conventional enclosed thermal current
20 A
[Ui] rated insulation voltage
600 V 3)IEC 609470-1
600 V 3)UL 508
600 V 3)CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
2.5 kV AC for 1 minute CE
2.2 kV AC for 1 minute UL
2.64 kV AC for 1 minute CSA
Short-circuit protection
20 A Bussmann class CC KTK-R-21 fuse non-time delay
Height
4.66 in (118.36 mm)
Net Weight
2.5 lb(US) (1.13 kg)
Terminals description ISO n°1
B (right side contact)
A (left side contact)