XCKM515

Limit switch, Limit switches XC Standard, XCKM, thermoplastic roller lever, 1NC+1 NO, slow break, Pg11

arrow

Commercialized

green premium

Expand all

Datasheet

Range of Product
Telemecanique Limit switches XC Standard
Series name
Standard format
Product or Component Type
Limit switch
Device short name
XCKM
Body type
Fixed
Head type
Rotary head
Material
Metal
Body material
Zamak
Fixing Mode
By the body
Movement of operating head
Rotary
Type of operator
Spring return roller lever thermoplastic
Type of approach
Lateral approach, 2 directions
Cable entry
3 entries tapped for Pg 11 cable gland
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, break before make
Switch actuation
By 30° cam
Electrical connection
Screw-clamp terminals 1 x 0.5...2 x 2.5 mm²
Contacts insulation form
Zb
Number of steps
1
Positive opening
With
Positive opening minimum torque
2.21 lbf.in (0.25 N.m)
Minimum torque for tripping
0.89 lbf.in (0.1 N.m)
Minimum actuation speed
6 m/min
Maximum actuation speed
4.92 ft/s (1.5 m/s)
Contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A AC
[Ui] rated insulation voltage
300 VUL 508
500 V 3)IEC 60947-1
300 VCSA C22.2 No 14
Maximum resistance across terminals
25 MOhm IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV IEC 60664
6 kV IEC 60947-1
Short-circuit protection
10 A cartridge fuse gG
Electrical durability
5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical durability
15000000 cycles
Width
2.52 in (64 mm)
Height
2.52 in (64 mm)
Depth
1.18 in (30 mm)
Net Weight
0.62 lb(US) (0.28 kg)
Terminals description ISO n°1
(13-14)NO
(21-22)NC
Shock resistance
50 gn 11 ms IEC 60068-2-27
Vibration resistance
25 gn 10…500 Hz)IEC 60068-2-6
IP degree of protection
IP66 conforming to IEC 60529
IK degree of protection
IK05 conforming to IEC 62262
Electrical shock protection class
Class I IEC 61140
Class I NF C 20-030
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Protective treatment
TC
Product Certifications
UL
CSA
CCC
Standards
IEC 60947-5-1
IEC 60947-5-1
UL 508
IEC 60204-1
IEC 60204-1
CSA C22.2 No 14
Category
US1000T22416
Discount Schedule
000T
GTIN
3389110646542
Returnability
No
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
1.26 in (3.200 cm)
Package 1 Width
2.60 in (6.600 cm)
Package 1 Length
5.67 in (14.400 cm)
Package 1 Weight
11.29 oz (320.000 g)
Unit Type of Package 2
S02
Number of Units in Package 2
32
Package 2 Height
5.91 in (15.000 cm)
Package 2 Width
11.81 in (30.000 cm)
Package 2 Length
15.75 in (40.000 cm)
Package 2 Weight
22.80 lb(US) (10.341 kg)
Sustainable offer status
Green Premium product
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
RoHS exemption information
Yes
Circularity Profile
No need of specific recycling operations
Warranty
18 months

Expand all

Technical Drawings

Dimensions

epds

(1) 3 tapped entries Pg 11 cable gland

Ø : 2 elongated holes Ø 5.2 x 6.2

Mounting with Cable Entry

Position of Cable Gland

epds

(1) Recommended

(2) To be avoided

Mounting with Rotary Heads and Levers

Type of Cam

epds

(1) Recommended

(2) To be avoided

Wiring Diagram

2-pole N/C + N/O Break before Make, Slow Break

epds

Characteristics of Actuation

Switch Actuation by 30° Cam

epds

Functionnal Diagram

epds

(P) Positive opening point

(1) NC contact with positive opening operation

(2) Closed

(3) Open

Back to top

arrow