Maximum force for tripping
0.2 N lever fixing position in A
0.4 N lever fixing position in B
0.53 N lever fixing position in C
Minimum release force
0.05 N lever fixing position in A
0.1 N lever fixing position in B
0.13 N lever fixing position in C
Maximum permissible end of travel force
10 N lever fixing position in B
13 N lever fixing position in C
5 N lever fixing position in A
Tripping point
0.60 in (15.2 mm) lever fixing position in A
0.60 in (15.2 mm) lever fixing position in B
0.60 in (15.2 mm) lever fixing position in C
Maximum differential travel
0.02 in (0.53 mm) lever fixing position in C
0.03 in (0.7 mm) lever fixing position in B
0.06 in (1.4 mm) lever fixing position in A
Minimum over travel
0.07 in (1.8 mm) lever fixing position in C
0.09 in (2.4 mm) lever fixing position in B
0.19 in (4.8 mm) lever fixing position in A
Inter contact distance
0.02 in (0.4 mm)
Contact code designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
[Ith] conventional free air thermal current
15 A 250 V 50/60 Hz
Mechanical durability
20000000 cycles
Net Weight
0.22 oz (6.3 g)
Terminals description ISO n°1
(1-2-4)OC