Switch actuation
By 30° cam
Electrical connection
Screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Contacts insulation form
Zb
Positive opening minimum force
40 N
Minimum force for tripping
16 N
Maximum actuation speed
3.28 ft/s (1 m/s)
[Ie] rated operational current
3 A 240 V, AC-15, A300 IEC 60947-5-1 appendix A
0.27 A 250 V, DC-13, Q300 IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
300 VUL 508
500 V 3)IEC 60947-1
300 VCSA C22.2 No 14
Maximum resistance across terminals
25 MOhm IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV IEC 60664
6 kV IEC 60947-1
Short-circuit protection
10 A cartridge fuse gG
Electrical durability
5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Mechanical durability
25000000 cycles
Net Weight
1.00 lb(US) (0.455 kg)
Terminals description ISO n°1
(13-14)NO
(21-22)NC