XUBLBNCNM12

Photoelectric sensors XU, XUB, thru beam, laser, Sn 100 m, 12...24 VDC, M12

arrow

Commercialized

green premium

Expand all

Datasheet

Range of Product
Telemecanique Photoelectric sensors XU
Series name
Application material handling
Electronic sensor type
Photo-electric sensor
Sensor name
XUB
Sensor design
Cylindrical M18
Detection system
Thru beam
Material
Metal
Type of output signal
Discrete
Supply circuit type
DC
Wiring Technique
3-wire
Discrete output type
NPN
Discrete output function
1 NO or 1 NC programmable
Electrical connection
1 male connector M12
Emission
Red laser class 1 0.000026378 in (670 nm) IEC 825-1
[Sn] nominal sensing distance
328.08 ft (100 m)
Enclosure Material
Nickel Plated Brass
Lens material
PMMA
Blind zone
0.00 in (0 mm)
Output Type
Solid state
Status LED
Supply on and teaching 1 LED green)
Stability 1 LED red)
Output state and alignment aid 1 LED yellow)
[Us] rated supply voltage
12...24 V DC reverse polarity protection
Supply voltage limits
10…30 V DC
Switching capacity in mA
<= 100 mA overload and short-circuit protection)
Switching frequency
1500 Hz
Maximum voltage drop
<1.5 V closed state)
Current consumption
25 mA no-load
Maximum power consumption in W
1 W
Maximum delay first up
80 ms
Maximum delay response
0.4 ms
Maximum delay recovery
0.4 ms
Setting-up
With sensitivity adjustment
Net Weight
0.29 lb(US) (0.13 kg)
Kit composition
Transmitter + receiver XUBLBKCNM12T + XUBLBNCNM12R
Product Certifications
UL
CSA
CE
Ambient Air Temperature for Operation
14…113 °F (-10…45 °C)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Vibration resistance
7 gn +/- 0.75 mm 10…55 Hz) IEC 60068-2-6
Shock resistance
30 gn 11 ms) IEC 60068-2-27
IP degree of protection
IP67 IEC 60529 double insulation)
Category
US10DS222481
Discount Schedule
0DS2
GTIN
3389119021036
Returnability
No
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
1.42 in (3.6 cm)
Package 1 Width
2.76 in (7.0 cm)
Package 1 Length
5.12 in (13.0 cm)
Package 1 Weight
4.48 oz (127.0 g)
Sustainable offer status
Green Premium product
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
Environmental Disclosure
Circularity Profile
Warranty
18 months

Expand all

Technical Drawings

Dimensions

epds

Dimensions

epds

Mounting

Adjustment

epds
  • (1) Adjust the focusing point of the laser beam by rotating the serrated sleeve
  • (2) Located on the face of the sensor. Re-tighten fixing screws

Wiring Schemes

M12 Connector

epds
  • 1 : (+)
  • 2 : Beam break input
  • 3 : (-)
  • 4 : OUT/Output

Wiring Schemes

NPN

epds
  • 1 : (+)
  • 2 : Beam break input
  • 3 : (-)
  • 4 : OUT/Output

Wiring Schemes

Transmitter

epds
  • 1 : (+)
  • 2 : Beam break input
  • 3 : (-)
  • 4 : OUT/Output
  • BN : Brown
  • BU : Blue
  • Input 2/VI : Not connected: beam made, connected to (-): beam broken

Curves

Detection Curve (Set to Infinity)

epds

Curves

Excess Gain Curve

epds
  • (X) Distance (m)
  • (Y) Gain

Curves

Standard Curve

epds
  • (X) Distance (m)
  • (Y) Gain
  • (X) Distance focusing point (m)
  • (Y) Minimum size of the object to be detected (mm)

Curves

Detection Limit Curve

epds
  • (X) Distance (m)
  • (Y) Gain
  • (X) Distance focusing point (m)
  • (Y) Minimum size of the object to be detected (mm)
  • (X) Distance focusing point (m)
  • (Y) Minimum size of the object to be detected (mm)

Back to top

arrow