Tags material
Tinned brass
Maximum force for tripping
0.83 N lever fixing position in A
1.67 N lever fixing position in B
Minimum release force
0.27 N lever fixing position in A
0.53 N lever fixing position in B
Maximum permissible end of travel force
3.33 N lever fixing position in A
6.67 N lever fixing position in B
Tripping point
0.57 in (14.5 mm) lever fixing position in B
0.61 in (15.5 mm) lever fixing position in A
Maximum differential travel
0.01 in (0.2 mm) lever fixing position in B
0.02 in (0.39 mm) lever fixing position in A
Minimum over travel
0.04 in (0.9 mm) lever fixing position in B
0.07 in (1.8 mm) lever fixing position in A
Inter contact distance
0.02 in (0.4 mm)
Contact code designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
[Ith] conventional free air thermal current
7.5 A 250 V 50/60 Hz
Mechanical durability
2000000 cycles
Net Weight
0.11 oz (3.2 g)
Terminals description ISO n°1
(1-2-4)OC