ZMLPA1P2SW

Electronic pressure sensors, Pressure sensors XM, Display & switch ZMLP, 24 VDC, 4...20 mA, PNP, window, M12

arrow

Commercialized

green premium

Expand all

Datasheet

Range of Product
OsiSense XM
Product or Component Type
Electronic pressure sensors
Device short name
ZMLP
Display Range
-14.5...6000
[Us] rated supply voltage
24 V DC SELV 17…33 V)
Current Consumption
<= 50 mA
Electrical connection
Female connector M12, 2 pins
Male connector M12, 4 pins
Type of output signal
Analogue + discrete
Analogue output function
4...20 mA
Discrete output type
Solid state PNP, NO/NC programmable
Switching function
Window
Maximum switching current
200 mA
Maximum voltage drop
2 V
Adjustable range of switching point on rising pressure
5…98 % of selected display range
Adjustable range of switching point on falling pressure
2…95 % of selected display range
Minimum differential travel
3 % of selected display range
Marking
CE
Front material
Polyester
Housing material
PBT Valox
Operating position
Any position
Protection Type
Overvoltage protection
Reverse polarity
Short-circuit protection
Overload protection
Response time on output
<= 3 ms analog output
<= 3 ms discrete output
Display type
4 digits 7 segments
Local signalling
for light ON when switch is actuated 1 LED (yellow)
Response Time
300 ms
Maximum delay first up
100 ms
Accuracy
<= - 0.1 % of the measuring range
Measurement accuracy
<= 1 % of the measuring range
Display accuracy
<= 1 % of the measuring range
Mechanical durability
10000000 cycles
Depth
1.65 in (42 mm)
Height
3.03 in (77 mm)
Width
1.61 in (41 mm)
Net Weight
0.23 lb(US) (0.103 kg)
[Uimp] rated impulse withstand voltage
0.5 kV DC
Product Certifications
cULus
Standards
IEC 61000-6-2
UL 508
IEC 61000-6-4
Ambient Air Temperature for Operation
-13…158 °F (-25…70 °C)
Ambient Air Temperature for Storage
-22…176 °F (-30…80 °C)
IP degree of protection
IP67 conforming to IEC 60529
IP65 conforming to IEC 60529
IP69K conforming to DIN 40050
Vibration resistance
5 gn 10…2000 Hz)IEC 60068-2-6
Shock resistance
25 gn IEC 60068-2-27
Electromagnetic compatibility
Immunity to conducted RF disturbances 10 V 0.15...80 MHz IEC 61000-4-6
Surge immunity test 1 kV IEC 61000-4-5
Electrical fast transient/burst immunity test 2 kV IEC 61000-4-4
Susceptibility to electromagnetic fields 10 V/m 80...2000 MHz IEC 61000-4-3
Electrostatic discharge immunity test 8 kV air, 4 kV contact IEC 61000-4-2
Category
US10DS222661
Discount Schedule
0DS2
GTIN
3389119617932
Returnability
Yes
Country of origin
FR
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
1.93 in (4.9 cm)
Package 1 Width
3.58 in (9.1 cm)
Package 1 Length
1.69 in (4.3 cm)
Package 1 Weight
3.74 oz (106.0 g)
Unit Type of Package 2
S01
Number of Units in Package 2
24
Package 2 Height
5.91 in (15.0 cm)
Package 2 Width
5.91 in (15.0 cm)
Package 2 Length
15.75 in (40.0 cm)
Package 2 Weight
5.97 lb(US) (2.707 kg)
Sustainable offer status
Green Premium product
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes

Expand all

Technical Drawings

Dimensions

epds

Dimensions

Switch with Metal Bracket for Fixing Horizontally

epds

Dimensions

Switch with Metal Bracket for Fixing Vertically or on an Inlet Pipe

epds

Connections and Schema

Output M12 Male Connector Wiring

epds
  • (1) Out
  • (2) I Out

Connections and Schema

Input M12 Female Connector Wiring

epds
  • (1) l in = 4-20 mA

Analog Output Description

epds
  • X : Pressure
  • Y : Analog output signal

The 4…20 mA analog output is strictly the image of the pressure transmitter output signal.

Switching Output Description. Window Mode

epds
  • X : Time
  • Y : Pressure
  • (1) Output
  • NP : Nominal pressure
  • FH : High switching point (adjustable from 5 % to 98 % NP)
  • FL : Low switching point (adjustable from 2 % to 95 % NP)

The window switching mode is typically used for the pressure regulation applications

Back to top

arrow